Products
New Energy Vehicle Cable
video
New Energy Vehicle Cable

New Energy Vehicle Cable

• Conductor: high-flex multi-strand bare copper
• Insulation: halogen-free cross-linked elastomer
• Shielding: none / braided copper ≥85%
• Voltage: 600/1000/1500V DC HV, 60V DC auxiliary
• Conductor: 2.5-200mm² HV; 2.5-70 shielded; 0.5-6 LV
• Bending: ≥5×OD unshielded, ≥6×OD shielded
• Custom: section, structure, color, stripping, crimping, assembly

Product Description

 

New Energy Vehicle Cable is built for electric vehicle power transmission, using high-flex multi-strand bare copper conductor and halogen-free cross-linked elastomer insulation. It delivers high/low temperature resistance, flame retardancy, oil resistance, and electromagnetic shielding performance.

 

It provides stable power connection for new energy passenger cars, commercial vehicles, and charging equipment, with unshielded and shielded versions plus a low-voltage auxiliary cable.

 

Parameters

 

Core Parameter

Standard Unshielded HV Cable

Shielded HV Cable

Low-Voltage Auxiliary Cable

Rated Voltage

600V / 1000V / 1500V DC

600V / 1000V DC

60V DC

Conductor Size

2.5 - 200 mm²

2.5 - 70 mm²

0.5 - 6 mm²

Shielding

None

Braided Copper (≥85% coverage)

Optional (signal only)

Min. Bending Radius

≥ 5× OD

≥ 6× OD

Less restricted

Typical Application

Battery internal wiring, main circuit

Motor, inverter, high anti-interference scenarios

Auxiliary power, sensors

 

Note: Conductor cross-section, cable outer color, finished harness processing can be customized as customer demands.

 

Core Selling Points

 

1. Wide Temperature Adaptability

The halogen-free insulation keeps stable flexibility across the stated vehicle cabin and engine-compartment temperature range, resisting hardening or cracking.

2. Flame Retardant and Environmental Safety

The halogen-free low-smoke formula releases little toxic gas when burning, supporting safety requirements for vehicle high-voltage circuits.

3. Shielded Version Anti-Interference

The dense copper braid isolates EMI from vehicle electronics, keeping power stable between drive motor and controller.

4. Oil and Abrasion Resistance

The outer sheath resists engine oil, coolant, and daily friction, fitting the narrow wiring routes inside the body.

5. Two Specifications for Onboard Demands

Unshielded EV suits conventional power loops, and shielded EVP suits high-frequency, high-interference areas, covering the whole-vehicle wiring scheme.

 

Customization Options

 

  • Conductor: High flexible bare annealed copper, multiple cross section from 2.5mm² to 120mm² available
  • Structure: Non-shielded EV / Shielded EVP two structural options
  • Outer color: Standard orange, black, red and other customized colors
  • Deep processing: Cable stripping, terminal crimping and finished cable assembly

 

new-energy-vehicle-cable-similar-products

 

Applications

 

  • New energy pure electric or hybrid vehicle high-voltage battery wiring.
  • Drive motor, vehicle inverter, and electric control system connections.
  • Onboard charger and DC-DC power conversion equipment internal wiring.
  • New energy engineering vehicles and AGV power transmission circuits.
  • Vehicle charging pile internal connecting wiring.

new-energy-vehicle-cable-application-scenario

 

Our Advantages

 

1)We manufacture connectors and cable assemblies in-house, covering stamping, injection molding, prototyping, assembly, and custom packaging.
2)Engineering support runs from the first drawing to delivery, including CAD drawings, 3D models, prototypes, and test samples tailored to the application.
3)Our interconnect products serve consumer electronics, data storage, medical, security, industrial, audio/video, and computing equipment across different markets.
4)Production balances consistent quality with competitive pricing, with materials and finishes selected for the stated operating conditions.
5)Our quality policy is Quality First, Customer First, with the order and after-sales follow-through handled as one engagement.

 

5-STAR REVIEWS FROM CUSTOMERS

 

Mike R., EV Battery Pack Engineer, Michigan
"The XLPE/TPU jacketed cable in the pack internal wiring balanced flexibility and cut-through resistance, and the orange jacket matched the harness color code."

Jessie L., Motor Control Integrator, California
"The braided shielded NEV cable on the inverter-to-drive run cleared the encoder noise that the unshielded version had caused, and the sheath routed without cracking."

Carlos M., Charging System Designer, Germany
"The flexible cable from the charging port to the battery handled the repeated rear-hatch motion and kept the insulation resistance up."

Sarah K., Electric Off-Highway Vehicles, Texas
"The NEV-grade cable on the skid steer held up to DEF and hydraulic oil exposure, and the jacket stayed flexible at the cold-start temperature."

Dave P., PHEV Harness Designer, Florida
"Using the same orange jacket across the engine bay and battery pack zones simplified assembly, and the selected materials matched each zone's temperature and oil needs."

 

FAQ

 

Q: What conductor and insulation are used?

A: High-flex multi-strand bare annealed copper with halogen-free cross-linked elastomer insulation.

Q: What voltages are rated?

A: 600/1000/1500V DC for HV cable, 60V DC for low-voltage auxiliary cable.

Q: What conductor sizes are covered?

A: 2.5 to 200 mm² unshielded HV, 2.5 to 70 mm² shielded HV, 0.5 to 6 mm² auxiliary.

Q: What shielding options exist?

A: Unshielded EV for conventional power loops, braided copper EVP for high-interference areas.

Q: What bending radius applies?

A: ≥5× OD unshielded, ≥6× OD shielded; auxiliary cable less restricted.

Q: What deep processing can be done?

A: Cable stripping, terminal crimping, and finished cable assembly, with orange, black, red, or custom colors.

 

Company Profile

 

 

Production Lines And Inspection Equipments

 

product-750-674

 

Our Certificates

 

product-1920-779

 

Payment Method

 

  • Payment method: Credit card or T/T (optional for large amounts). Western Union PayPal
  • T/T payment generally supports 100% advance payment.
  • Lead time: Normally in 5-10 working days after payment received.
  • Sample policy: Samples are always available for each model for standard products.
  • Samples can be ready in 3-5 working days once payment received.
  • Shipping port: Shenzhen, China.

product-1201-158

 

Logistics/packaging

 

product-750-549

Hot Tags: new energy vehicle cable, China new energy vehicle cable manufacturers, suppliers, factory, Connection Wire, Electrical Connection Wire, Shielded Cable, Signal Cable, Single Core Wire, wire

Send Inquiry